数据中心验收(数据中心巡检)

What does data center epc mean?
EPC refers to the full-process engineering general contracting service such as engineering design, procurement and construction. It is a common model in modern engineering construction. Data center EPC specifically refers to the field of data center construction, which integrates engineering design, procurement, construction, commissioning, acceptance and other aspects, and provides full-process overall contracting services by one company.
The advantages of the data center EPC model are mainly reflected in three aspects. First, it can reduce project risks and ensure the smooth progress of the entire construction and operation process. Secondly, it can improve construction and operation efficiency, reduce communication links, and optimize efficiency and cost control. Finally, it can ensure the consistency of construction and operation and ensure safe and stable data center operation.
Application of data center EPC in construction and operation
With the development of the digital economy, the demand for data centers is increasing day by day. The data center EPC model has also become the first choice for data center construction and operation. This model is widely used in the installation of hardware equipment, power supply, network access, air conditioning and refrigeration, etc. In addition, the data center EPC model can also provide flexible customized services according to customer needs to meet various construction and operation needs.
Why does the data center computer room need third-party acceptance? How to carry out acceptance? ? What is the standard? Is it authoritative?
Data center acceptance is very important. Data center construction involves 8 major subsystems, more than 10 disciplines, and only thousands of product models and types. How to ensure that the construction and products meet the design and construction requirements and conduct acceptance Very important. There are relevant requirements for construction and acceptance in GB50462-2008. But despite this, errors in design and construction are inevitable, especially the connection between processes is very prone to problems. These problems may lead to low efficiency of the system, increase operation and maintenance costs, and may affect the safe and reliable operation of the entire data center. Especially in the early stages of operation, many problems are not easy to detect, leaving hidden dangers for the safe and reliable operation of the system.
For data centers, "physical examination" before powering on is very important. It is necessary to hire experts with rich experience to help conduct a comprehensive inspection of the status of the data center and conduct a final check. Whether it is design errors, quality issues during construction, or product quality issues, conduct a comprehensive inspection. Rectify what you find. At this stage, the cost of rectifying problems is relatively small. Once the data center is powered on and then rectified, because the system needs to keep running, the cost is like replacing the engine of a flying airplane. The difficulty and cost are unimaginable. Therefore, considering the huge investment in the data center, it is very important and necessary to conduct a physical examination. It needs to be paid great attention to.
As for the third party, it has no interest in Party A and Party B, and is only responsible for professionalism, so it is necessary. You know the truth.
For third parties, what is important is not their qualifications, but their understanding of the data center, testing methodology, means and testing content. Look at the cases they have tested. After all, this is a matter that relies on expert experience. Experience needs to be accumulated and cannot be achieved overnight. As for the cost, it’s fine as long as it’s reasonable and you don’t need to pay too much attention to it. Professionalism is the most important thing.
Even if no problems are found in the physical examination, it is still very worthwhile. After all, with an extra layer of security, you can feel more at ease.

Does the host reception include the computer room layer?
It does. The main purpose of the main acceptance is to inspect and confirm the construction of the computer room layer and the installation, configuration and operation of facilities and equipment to ensure the operational safety and quality of the data center and to meet business requirements. The computer room layer is an indispensable part to complete the main experience acceptance, and is an important component that must be inspected and accepted to implement the main experience acceptance. Also examine the data center operating environment and energy consumption.

What tools are needed for data center acceptance?
Philips and slotted screwdrivers, multimeters, ammeters, needle-nose pliers, anemometers, dummy loads (1000W electric furnace), and a "Test and Acceptance Form" need to be prepared.
According to relevant information on , the data center has acceptance work, and the tools required for acceptance are: cross, slotted screwdriver, multimeter, ammeter, needle nose pliers, anemometer, dummy load (1000W Electric furnace), you also need to prepare a "Testing and Acceptance Form".
Acceptance, inspect according to certain standards and then accept or approve item-by-item acceptance.