How the financial industry builds a new generation of data center power platform and a new generation of data center
The financial industry is a pioneer in data center applications. In recent years, from large-scale data concentration to multi-business integration, the construction of data centers in the financial industry is rapidly evolving around the needs of business development. Now, a large concentration of data in the financial industry has taken shape. Facing new demands and industry development status, financial companies are focusing on the construction of new generation data centers. In this process, four major challenges have become increasingly prominent: data center security, data center energy saving and consumption reduction, data center management and maintenance, and data center expansion. As a data center infrastructure, the construction of power platform first needs to solve the following four problems.
First, the issue of reliability. Power supply reliability is an important guarantee for data center security. With the continuous emergence of new businesses supported by information technology, the requirements for power supply reliability in data centers in the financial industry have greatly increased. In the field of data centers, the availability index of the power platform is higher than the availability index of the data center and the availability index of the entire network system. Therefore, the power platform should be placed at the core position. For example, if the redundancy method of server power supply has changed, the power supply system should make corresponding changes; the application of blade servers and virtualization has highlighted the problem of high heat density, making the computer room environment more severe, and the cooling mode needs to be changed.
Second, the issue of energy conservation and consumption reduction. The most direct consequence of the acceleration of data center construction is the sharp increase in energy consumption. In the context of the current global energy shortage, energy conservation and consumption reduction are a major trend in the entire data center industry. my country has defined the IT industry as the third category of energy conservation and consumption reduction industries. For the enterprise itself, the sharp increase in energy consumption has greatly increased the operating costs of the data center. Energy saving and energy efficiency improvement of the data center have become an urgent requirement for the entire industry.
Third, management and maintenance issues. The computer room is a large and complex system. At the infrastructure level, its power and environmental conditioning system covers a more diverse range of equipment, including UPS, air conditioners, server cabinets, batteries, input power distribution, oil machines, temperature and humidity, Smoke sensor, access control, infrared, etc. These systems are an organic whole, affecting the whole system. The reliability of the computer room depends on the normal operation of each device and the coordination of these devices. If any link fails, it may cause huge losses. Therefore, the management of the entire system is becoming more and more important and more and more difficult.
Fourth, the issue of expansion. With the continuous expansion of business volume, IT application systems in the financial industry are expanding day by day, and the scale of servers has become increasingly large, which has brought about problems such as high energy consumption, tight data center space, and tight IT budgets. At the same time, the matching of the data center power platform is not enough, either the utilization rate is low and resources are wasted seriously; or the power supply and cooling are obviously insufficient, affecting the availability of the data center. In short, the power system is not responsive enough to the power or cooling needs of core equipment.
In response to the above problems, Emerson Network Power launched the Emerson Financial Innovation Data Center Solution. This solution has four major characteristics: high availability, high energy saving, high flexibility, and high maintainability. It can help financial industry customers solve the problems of data center construction and application, and meet the requirements of financial enterprises for computer room power security in the informatization process. , energy conservation and environmental protection and other aspects of the growing application demand.
Specifically, in terms of availability, Emerson Network Energy Power Supply System ensures the most advanced availability and reliability through reasonable input power distribution design, different levels of UPS power supply system structures and solutions, and advanced output power distribution systems. sex. Its UPS power supply system is divided into 4 levels according to different protection levels. The highest level 4 uses symmetrical dual lines and the availability can reach 99.99999%. In terms of input power distribution, this solution provides a highly reliable design, which can ensure the selective coordination of distribution switches at all levels and has reasonable planning. In terms of output power distribution, Emerson server power management system can provide the most advanced and reliable power distribution for users' most critical loads.
In terms of energy saving, this solution is based on the "energy efficiency logic" energy saving strategy, using LiebertXD high heat density refrigeration system and efficient power supply system to achieve the best energy saving state of the data center. Its SPM server power management system can also detect the operating cost of each server rack in real time, accurately calculate and measure the power consumption and power consumption of each server cabinet and each switch, so as to carry out effective energy-saving management. In terms of maintenance and management, this solution uses an industry-leading monitoring and management platform to manage operating parameter reports for the computer room power system, safety system, air conditioning system, etc., and provide local and remote alarms for faults. In terms of flexibility, this solution allows the data center to follow the development strategy of "growing while investing" and ensures smooth expansion and upgrade of the data center.
In addition, Emerson Network Power’s strong engineering implementation capabilities and power service support capabilities can enable this solution to bring more application value to users in the financial industry. At present, this solution has been applied in key areas of the financial system such as the Clearing Center of the People's Bank of China, the Information Center of the Head Office of China Construction Bank, and the Information Center of the Bank of China, and has achieved good results.

What issues need to be paid attention to when constructing a data center computer room?

When constructing a data center computer room, the following issues need to be noted:

Site selection and load-bearing: after site selection , it is necessary to consider the load-bearing capacity of the building to avoid the need for reinforcement and transformation due to excessive weight. At the same time, consideration must also be given to the utilization of the space under the floor of the computer room to avoid affecting the air supply of the dedicated air conditioner in the computer room.

Layout design: It is necessary to reasonably design the layout of the computer room according to actual needs, including equipment area, test area, office area, etc. At the same time, consideration must be given to the installation, maintenance and management of equipment, as well as the operation and safety of staff.

Equipment selection: You need to select suitable equipment, including servers, storage devices, network equipment, etc. At the same time, factors such as equipment performance, reliability, maintainability and cost should be taken into consideration.

Power supply: Stable power supply is required, and UPS equipment should generally be equipped to cope with sudden power outages. At the same time, power distribution and management, as well as power backup and expansion, must be taken into consideration.

Air conditioning system: It is necessary to ensure the stable operation of the equipment and the appropriate temperature. Generally, professional air conditioning equipment should be equipped. At the same time, the energy saving and environmental protection of the air conditioning system must be taken into consideration.

Fire safety: Complete fire safety measures are required, including the setup and maintenance of access control systems, monitoring systems, alarm systems and other equipment to ensure the security of equipment and data in the computer room.

Environmental monitoring: It is necessary to monitor the environmental conditions of the computer room, including temperature, humidity, smoke concentration, etc., in order to detect abnormal situations in time and take corresponding measures.

Lightning protection and grounding: The issue of lightning protection and grounding needs to be considered to protect equipment and personal safety.

Construction safety: During the construction process, the safety of workers should be taken into consideration, such as wearing protective equipment and avoiding working at high altitudes.

Acceptance testing: After the construction is completed, acceptance testing is required to ensure that the construction of the computer room meets the requirements of relevant standards and specifications.

In addition, you need to pay attention to the following points:

Computer room dust removal and environmental requirements: Regularly remove dust from the equipment, clean it, and adjust the clarity of the security camera to prevent static electricity due to machine operation. and other factors will suck dust into the monitoring equipment. At the same time, check the ventilation, heat dissipation, dust purification, power supply, overhead anti-static floor and other facilities in the computer room. The indoor temperature of the computer room should be 20±2℃ and the relative humidity should be controlled at 45%~65% according to the corresponding specifications.

Machine room air conditioning and fresh air maintenance: Check whether the air conditioner is operating normally and whether the air exchange equipment is operating normally. Observe the refrigerant level through the sight glass to see if there is a lack of refrigerant. Check the air conditioning compressor high and low pressure protection switches, drying filter and other accessories.

Selection of materials for computer room construction: Considering the special nature of the computer room, materials with fireproof, waterproof, dustproof and other properties should be selected to build the computer room. At the same time, the weight and strength of the material must also be considered to ensure the safety and stability of the computer room.

Computer room noise control: Due to the large number of equipment in the computer room, loud noise may be generated. Therefore, noise control issues need to be considered when designing and building computer rooms to provide a quiet working environment.

Energy conservation and environmental protection of computer rooms: Energy conservation and environmental protection issues need to be considered when designing and constructing computer rooms, and energy-saving equipment such as efficient air conditioning systems and lighting systems should be used to reduce energy consumption and impact on the environment.

Computer room safety precautions: In order to ensure the safety of the computer room, a series of safety precautions need to be taken. This includes the setup and maintenance of access control systems, monitoring systems, alarm systems and other equipment to ensure the security of equipment and data in the computer room.

Computer room acceptance standards: After the construction of the computer room is completed, acceptance testing is required to ensure that the construction of the computer room meets the requirements of relevant standards and specifications. The acceptance criteria include the layout of the computer room and the installation of equipment, the operation of power supply and UPS systems, the operation of air conditioning systems and environmental monitoring equipment, etc.

In summary, many issues need to be considered when constructing data center computer rooms, including but not limited to site selection and load-bearing, layout design, equipment selection, power supply, air conditioning systems, etc., as well as fire protection and waterproofing Safety issues such as , dust prevention, environmental protection and energy saving issues need to be carefully considered.

Data Center IDC Computer Room Construction Standards

1. Site selection and layout: The location of the computer room should be away from strong noise sources, dust, oil fumes, harmful gases, and away from strong electromagnetic field interference. The layout design needs to consider process requirements and distribution of functions, and plan the computer room area and equipment spacing according to the number of computer equipment and cabinets.

2. Architecture and structure: The computer room building should have good wind resistance, earthquake resistance, flood prevention, and fire resistance. The structural design requires that it be strong, stable, and able to bear the equipment and weight in the computer room.

3. Electrical system: The computer room should be equipped with dual-channel mains introduction to ensure the stability of power supply. At the same time, the computer room also needs to be equipped with UPS power supply and battery pack to cope with sudden power outages. In addition, the computer room should be equipped with power distribution cabinets, lighting, emergency lighting, sockets and other facilities to meet the work needs of the equipment and personnel in the computer room.

4. Air conditioning and ventilation: The computer room should be equipped with precision air conditioning to maintain a constant temperature and humidity environment. At the same time, the computer room also needs to be equipped with a fresh air ventilation system to ensure the air quality and ventilation requirements in the computer room.

5. Fire protection system: The computer room should be equipped with fire alarm systems, portable fire extinguishers and other fire protection facilities to ensure the safety of the computer room.

6. Network and communications: The computer room should have anti-static floors and a grounding system to prevent static electricity from damaging equipment. At the same time, the computer room also needs to be equipped with network cabling, communication equipment and other facilities to meet the network communication needs of the data center.

7. Security and monitoring: The computer room should be equipped with access control, surveillance cameras and other security facilities to ensure the safety of the computer room. At the same time, the computer room also needs to be equipped with a dynamic environmental monitoring system to monitor the environment and equipment in the computer room in real time to ensure the stable operation of the computer room.

8. Decoration and decoration: The decoration of the computer room must be simple, practical and easy to maintain. Decoration materials should be fireproof, moisture-proof, and anti-static.